Filter Results By:

Products

Applications

Manufacturers

Showing results: 391 - 405 of 674 items found.

  • High Voltage Impulse Test Set Up

    NEO TELE-TRONIX PVT. LTD

    We are renowned as the foremost manufacturer and exporter of High Voltage Impulse Test Set Up. This testing equipment is demanded in electrical, power generation and engineering sector. It is incorporated with fiber optic isolated digitizers to test various types of transformers. We utilize excellent grade raw materials to engineer and develop this High Voltage Impulse Test Set Up in accordance with industry standards. Our clients can get this equipment from us at competitive price.

  • Crawler Control Unit

    CCU186 - Teledyne ICM

    The CCU186 control unit for crawlers possesses a distinct advantage compared to existing products. In fact, all of the performances that are usually achieved with standard control units are now available in the crawler configura­tion. Automatic slow preheating, the progressive rise in voltage with each exposure, as well as a selection of set values are all included in the CCU186.As the CCU186 has been entirely fitted with industrial electronic components, it is perfectly suited to the often extreme conditions of automatic intra-tube control campaigns.

  • Field Intensity Meter

    LM870-W - Sichuan Jiuzhou Electronic Technology Co.,Ltd

    * Trunk-line AC voltage, V/A, C/N and TILT measurable* Automatic over-voltage shut-off protection* AC/DC optional (Ni-H/Li storage battery inside)* Full-digital key-board operation, direct freq. & channel input* Automatic scanning, Automatic channel-filtering, Automatic error-operation amending* All standard channels and subjoin channels pre-set inside* New channel-table setting according to user's special requirement* Spectrum displaying* English/Chinese operation interface* Audio output (speaker set-in)

  • Frequency to Current Converter

    DAT4540R - Datexel

    The Frequency to Current converter DAT4540R is a signal conditioning din rail mount converter which converts a pulse input to an analog output equal to the set range which is selectable from 0.1 Hz up to 20 KHz. The DAT4540R also provides 2 relay outputs and a transistor output. The input can be from a Tacho, TTL, PNP transistor or from any Namur standard. The DAT4540R provides a Voltage or Current output that is isolated from the power supply and input.

  • Hand-hold Field Intensity Meter

    LM870-N - Sichuan Jiuzhou Electronic Technology Co.,Ltd

    * Trunk-line AC voltage, V/A, C/N and TILT measurable* Automatic over-voltage shut-off protection* AC/DC optional (Ni-H/Li storage battery inside)* Full-digital key-board operation, direct freq. & channel input* Automatic scanning, Automatic channel-filtering, Automatic error-operation amending* All standard channels and subjoin channels pre-set inside* New channel-table setting according to user's special requirement* Spectrum displaying* English/Chinese operation interface* Audio output (speaker set-in)

  • Mini Redundant Power Supply; ATX 500W

    PS500-HRP - Axiomtek Co., Ltd.

    *Input Range: 100~ 240VAC Full Range*Output Voltage:**+5V, 25A (1A min)**+3.3V, 25A (1A min)**+12V, 41A (1A min)**-12V, 0.8A**-5Vsb, 3.5A (0.1A min)*MTBF(hours): AT 25°C 100,000h*Safety: UL, TUV, CB, CCC, RFI/EMI Standards, FCC Class B, CISPR22 Class B*Dimensions: 185 x 150 x 86 mm*Compatible with Axiomtek products: AX61492

  • Partial Discharge Test Set

    NEO TELE-TRONIX PVT. LTD

    We are an unparalleled name in the industry, engaged in manufacturing and exporting Partial Discharge Test Set that is broadly used for instrument transformers to test the discharge of voltage. This test set is manufactured in compliance with set international quality standards using optimum quality components under the observations of our experienced professionals. Further, it is made available in several specifications to meet the exact requirements of the clients. Our offered Partial Discharge Test Set can be owned from us at nominal prices.

  • Quadrature Sensor

    SPECTEC Innovative Sensor Solutions

    DIGISPEC Hall Effect Quadrature Sensors provide two digital output signals, 90º out of phase to each other, detecting speed (down to true zero speed) and direction of rotation of gear teeth and ferrous targets. Gear teeth as small as module 0.10" wide can be sensed. Standard output is provided from a 2.2kOhm internal pull-down resistor to a collector, which can sink 25 mA. Open collector can be provided. Output is protected against reverse voltage.

  • Thermocouples

    WIKA Alexander Wiegand SE & Co. KG

    Thermocouples are temperature sensors that generate a voltage directly dependent on temperature. Compared to resistance thermometers, they are particularly suited for high temperatures up to 1,700 °C. Instrument designs from mineral-insulated sheathed cable are very resistant against extremely high vibration loads (depending on instrument model, sensor element and wetted materials). The accuracy classes 1 and 2 apply for thermocouples in accordance with IEC 60584 as well as the standard and special classes in accordance with ASTM E230.

  • Timer, Delay-Off, 4 Pole

    TDE4N relay - - Mors Smitt Group

    Plug-in electronic industrial timer relay with four change-over contacts. When the relay is de energized there is a delay on drop-out without any auxiliary power supply. The delay time is adjustable with a lockable knob. The relay can also be supplied with a fixed time delay (no knob).The relay is equipped with a LED which indicates the presence of energizing voltage. Standard equipped with back EMF suppression. Optionally equipped with magnetic arc blow-out for high breaking capacity and long contact life.

  • PWM TO VOLTAGE SIGNAL CONVERTER

    RCPWM2V - Astro Flight Inc.

    The RCPWM2V is a device that converts a standard hobby RC signal (1-2ms pulse) into a proportional analog voltage (0-5V). In many electronics applications the main processor is constantly busy and does not have the ability to address the time-sensitive PWM signal from an RC receiver immediately. This results in signal distortion or a sluggish response due to the extra filtering required. The RCPWM2V provides a simple solution by converting the signal into an analog signal. The main processor can then read the signal whenever it has time.

  • Plant Auditor's Surface Resistance Kit

    PMK-153 - Prostat Corporation

    The PMK-153 Resistance Test Kit contains the instruments you need to take resistance measurements.The PMK-153 includes the PAS-853B Wide Range Ohmmeter with 5 pound Conductive Rubber Electrodes. The PAS-853B instrument is a wide range ohmmeter that measures accurately from 0.01 to 9.9x1012 ohms. In AUTO mode the instrument automatically adjusts resistance range and selects test voltage in accordance with standard practices outlined in ANSI/ESD STM11.11, and meets audit requirements of ESD TR53.

  • Dual Channel Tri-Level Driver Card

    40465 - Pulse Instruments

    Two channels of 10MHz drivers, that can be operated as standard Two-Level Drivers or operated as two channels of Tri-Level Drivers. In the Two-Level mode, the input to each driver channel requires one channel of TTL level timing. Tri-and four level modes require a second clock input. In the Tri-Level Mode, the output from lowest rail to high rail can be 18.5V. Like the 40460 the rise and fall time as well as the high and low voltage levels of each channel is programmable.

  • AC Power Supplies

    BLC Series - Behlman Electronics Inc.

    The BLC Series delivers all the quality features our customers have come to expect from Behlman; clean sine wave output with excellent line and load regulation, high efficiency and low harmonic distortion. A multi-pulse input transformer offers low-input harmonic distortion and high power factor as required by European standards. Unique protection circuitry provides for over-temperature protection; short-circuit protection and voltage fold-back during overloads to maintain undistorted waveforms.

  • Energy Meter Test Bench

    SP-6103 - Shanghai Powoo Industry Develop Group Limited

    - Single phase energy meter test bench - auto-calibration system - accuracy class: 0.1/0.2 class - Standard CT; 0.01/0.02 - output voltage: 0-220V9240V option); range: 0-120% - fine adjustment: 0.01% - output current: 0-100A; (option for 200A)- fine adjustment: 0.0001A (min)

Get Help